Product Overview

In recent times, pharmaceutical companies have started developing more and more concentrated medicines. These medicines need to be injected continuously as well as slowly into the patient. Syringe pumps are highly helpful under such situations as they can be programmed to deliver a specified quantity of drug through the vein at a predetermined rate. Our AKAS TERUMAX RX is a Syringe Infusion Pump that can deliver Critical Care drugs to patients in a controlled state. Can be used in Adult, Pediatric and Neonatal Patients. The device comes with a drug library as well as a body mass based drug calculation

Features
  • Suitable for Cardiothoracic patients
  • Compact & light weight (1.5Kg)
  • Anti-bolus function
  • Drug Library (100 drugs) with auto flow rate calculation
  • Event log
  • Real time clock
  • Hospital Name display
  • 2ml, 5ml, 10ml, 20ml, 50/60 ml syringe applicable
  • LCD Display with user assist menu
  • 0.01 ml/ht to 1500 ml/hr flow rate
  • Patient end delivery line disconnection alarm
  • Battery back up to 8 hrs
  • Front loading operation
  • Stackable up to 4 pumps
  • Multiple safety alarm facility
  • Dosage ramp up and taper down program
  • Custom programmable mode to accept any brand of syringe
  • Automatic Syringe Size Detection
  • In line program during infusion
  • KVO function
  • Target Volume & Time Setting
  • Infused Volume & Time Display
  • Upgradable to PCA
  • Bolus Function
  • Variable Occlusion Pressure
  • ‘Syringe not engaged’ alarm during infusion
  • LCD, LED Display & User Friendly Operation
Technical Specifications
  • Power Supply : DC 18V (1A) / 220 V AC
  • Battery : 12V (800 mAh) NiMH Battery
  • Battery Backup : 8hrs @ 5ml.hr Flow rate on 50ml Syringe
  • Power Consumption : 7 VA
  • Display : LCD & LED Display
  • Applicable Syringe : 2ml, 5ml, 10ml, 20ml, 30ml, 50/60ml & 100ml Syringes form any brand. Custom Programmable for any brand Syringe also available
  • Automatic Syringe Size Detector : Available
  • Flow Rate Range : 0.01 – 100 ml/Hr (2ml Syringe)
    0.1 – 200 ml/Hr (5ml Syringe)
    0.1 – 400 ml/Hr (10ml Syringe)
    0.1 – 600 ml/Hr (20ml Syringe)
    0.1 – 800 ml/Hr (30ml Syringe)
    0.1 – 1500 ml/Hr (50ml Syringe)
    0.1 – 1500 ml/Hr (100ml Syringe)
  • Infused Volume : 0.1 – 9999 ml
  • Elapsed Time : Display of Elapsed time from 00:01 to 199:59 hrs
  • Dosage Taper Up/Down (Sequential Mode) : Sequential program of 5 different Flow-rate at Different target time or volume available
  • KVO : 0.1ml/Hr to 9.9ml/Hr in 0.1 ml increment
  • Bolus : Purge Bolus & Auto Bolus
  • Bolus Flow Rate : 0.1 – 100 ml/Hr (2ml Syringe)
    0.1 – 200 ml/Hr (5ml Syringe)
    0.1 – 400 ml/Hr (10ml Syringe)
    0.1 – 600 ml/Hr (20ml Syringe)
    0.1 – 800 ml/Hr (30ml Syringe)
    0.1 – 1500 ml/Hr (50ml Syringe)
    0.1 – 1500 ml/Hr (100ml Syringe)
  • Bolus Volume : 0.1ml to 10 ml in 0.1 ml increments
  • Occlusion Pressure : 10 steps selection (OFF to 9 Levels)
  • Anti -Bolus function : Available
  • Event log with RTC : Available
  • Alarms : AL 1 – Syringe holder disturbed during infusion
    tAr.1 – Target Volume reached
    tAr.2 – Target time reached
    End – End of Syringe
    PCA.d – PCA Probe disconnected
    OccL – Occlusion
    OFF – Battery discharged
    AL 2 – Syringe not engaged
    AL 3 – Internal mechanism fault
  • Audio/Visual Indication & Alarms : Target reached (time or volume),Occlusion, Syringe not engaged, Near to Empty, End of syringe, Battery mode, battery low, Internal mechanism fault, KVO Mode, Bolus Mode, SpO2 Mode, SpO2 Hi/Low alarms, PCA Mode, PCA probe disconnected, Patient end drug line
  • Modes : Flow Rate only, Flow Rate & Target volume, Flow Rate & Target Time, Target volume and target time, Drug library mode, Syringe pump with pulse oximeter Mode
  • Drug Library : Available with 100 drug name.
    Flow rate calculation based on patient weight (Kg),
    Drug Concentration (mg/ml, mcg/ml) and
    Drug Dosage (mg/kg/hr, mc/kg/min,mcg/kg/hr,mcg/kg/min)
  • PCA (Optional) : PCA dose can be preset from 0.1 to 10ml.
    Minimum locking time interval between two Doses,
    Time interval from 0 – 24hrs in steps of 1 min,
    Delivered and non delivered doses display
  • Accuracy : Mechanical Accuracy ±1%, Including Syringe ± 3%
  • Safety Testing : EN 60601-1. EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24
  • Certification : CE, ISO 13485:2003, ISO 9001:2008
  • Space Occupie : 2.4 ltrs
  • Weight : 1.5 kg
  • Dimension : 170 x 107 x 135 ( L x B x H)