SYRU 6006

Syringe pump – AKAS SYRU 6006
Product Overview

AKAS SYRU 6006 is an advanced Syringe Pump manufactured by AKAS. This is having linear smooth flow and accurate dynamic pressure display which helps some of important medication process very much. Our AKAS SYRU 6006 can deliver Critical Care drugs to patients in a controlled state. Can be used in Adult, Pediatric and Neonatal Patients. The device comes with a drug library as well as a body mass based drug calculation

Features
  • Suitable for Cardiothoracic patients
  • Dynamic pressure display
  • Compact & light weight (1.85Kg)
  • Anti-bolus function
  • Drug Library (100 drugs) with auto flow rate calculation
  • Event log
  • Real time clock
  • Hospital Name display
  • 2ml, 5ml, 10ml, 20ml, 50/60 ml syringe applicable
  • LCD Display with user assist menu
  • 0.01 ml/ht to 3000 ml/hr flow rate
  • WiFi communication
  • RS232 communication
  • Patient end delivery line disconnection alarm
  • Battery back up to 8 hrs
  • Front loading operation
  • Stackable up to 4 pumps.
  • Multiple safety alarm facility.
  • Dosage ramp up and taper down program.
  • Custom programmable mode to accept any brand of syringe.
  • Automatic Syringe Size Detection.
  • In line program during infusion.
  • KVO function.
  • Target Volume & Time Setting.
  • Infused Volume & Time Display.
  • Upgradable to PCA.
  • Bolus Function
  • Variable Occlusion Pressure.
  • ‘Syringe not engaged’ alarm during infusion.
  • LCD, LED Display & User Friendly Operation.
Technical Specifications
    • Power Supply : 220 V AC
    • Battery : 12V (800 mAh) NiMH Battery
    • Battery Backup : 8hrs @ 5ml.hr Flow rate on 50ml Syringe
    • Power Consumption : 7 VA
    • Display : LCD & LED Display.
    • Applicable Syringe : 2ml, 5ml, 10ml, 20ml, 30ml & 50/60ml from any brand. Custom Programmable for any brand Syringe also available.
    • Automatic Syringe Size Detector : Available
    • Flow Rate Range : 0.01 – 350 ml/Hr (2ml Syringe)
      0.1 – 750 ml/Hr (5ml Syringe)
      0.1 – 1000 ml/Hr (10ml Syringe)
      0.1 – 1800 ml/Hr (20ml Syringe)
      0.1 – 2500 ml/Hr (30ml Syringe)
      0.1 – 3000 ml/Hr (50ml Syringe)
    • Infused Volume : 0.1 – 9999 ml
    • Elapsed Time : Display of Elapsed time from 00:01 to 199:59 hrs
    • Dosage Taper Up/Down : Sequential program of 10 different Flow-rate at Different target (Sequential Mode)time or volume available.
    • KVO : 0.1ml/Hr to 9.9ml/Hr in 0.1 ml increment.
    • Bolus : Purge Bolus & Auto Bolus
    • Bolus Flow Rate : 0.01 – 350 ml/Hr (2ml Syringe)
      0.1 – 750 ml/Hr (5ml Syringe)
      0.1 – 1000 ml/Hr (10ml Syringe)
      0.1 – 1800 ml/Hr (20ml Syringe)
      0.1 – 2500 ml/Hr (30ml Syringe)
      0.1 – 3000 ml/Hr (50ml Syringe)
    • Bolus Volume : 0.1ml to 10 ml in 0.1 ml increments
    • Occlusion Pressure : 10 steps selection (OFF to 9 Levels).
    • Anti -Bolus function : Available.
    • Event log with RTC : Available.
    • Alarms : AL 1 – Syringe holder disturbed during infusion.
      tAr.1 – Target Volume reached.
      tAr.2 – Target time reached.
      End – End of Syringe.
      PCA.d – PCA Probe disconnected.
      OccL – Occlusion.
      OFF – Battery discharged.
      AL 2 – Syringe Disturbed during infusion
      AL 3 – Internal mechanism fault.
      AL4 – Mains to battery F/R high Reduce to 2000ml/hr
      AL 5 – Mains Voltage over the limit
      AL 6 – Mains voltage below 215 V
      AL 9 – Syringe not engaged
      AL 10 – Occlusion sensor failed
    • Audio/Visual Indication & Alarms : Target reached (time or volume), Occlusion, Syringe not engaged, Near to Empty, End of syringe, Battery mode,battery low, Internal mechanism fault, KVO Mode, Bolus Mode, PCA Mode, PCA probe disconnected, Patient end drug line disconnected
    • Modes : Flow Rate only, Flow Rate & Target volume, Flow Rate &Target Time, Target volume and target time, Drug library mode
    • Drug Library : Available with 100 drug name,
      Flow rate calculation based on patient weight (Kg),
      Drug Concentration (mg/ml, mcg/ml) and Drug,
      Dosage (mg/kg/hr,mc/kg/min, mcg/kg/hr, mcg/kg/min)
    • PCA (Optional) : PCA dose can be preset from 0.1 to 10ml.

Minimum locking time interval between two Doses, Time interval from 0 – 24hrs in steps of 1 min, Delivered and non delivered doses display

  • Accuracy : Mechanical Accuracy ±1%, Including Syringe ± 3%
  • Safety Testing : EN 60601-1. EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24
  • Certification : CE, ISO 13485:2003, ISO 9001:2008
  • Space Occupied : 2.4 ltrs
  • Weight : 1.85 kg
  • Dimension : 170 x 107 x 135 ( L x B x H)

 

Contact Us to Get Quote