INFU 5005

AKAS INFU 5005
Product Overview

AKAS INFU 5005 volumetric cum Drop counting infusion pump combines high levels of safety and performance to provide for a very simple and reliable operation. It is designed in such as way that it offers several advanced features ideal for general, critical care, neonatal and cancer therapy infusions where accuracy is key. At their simplest, infusion pumps comprise of an user-interface that controls the electromechanical pumping mechanism which is responsible for driving fluid from a container (bag, bottle or syringe) through a flexible tubing into a patient’s catheter.

Features
  • Drop/min setting
  • Ml / hr setting
  • Infused volume & drops display
  • Elapsed time display
  • Target volume & Target time
  • setting – Auto calculation
  • Built in rechargeable battery
  • Excess/Less flow alarm
  • Less flow alarm due to occlusion
  • Programmable to any I.V tubing
  • Suitable for micro / Adult infusions
  • Audible and visual alarms
  • Keep vein open(KVO)
  • ‘Air in Line’ Detector
  • Bolus Function
  • Different colour LED’s &
  • LCD Display with Help Function
  • Free Flow Protection
Technical Specifications
  • Power Supply : AC 220V to 240V 50Hz
  • Battery Backup : 4hrs @ 8 drop/min or 25 ml/hr (Auto Power Saving Mode)
  • Power Consumption : 10VA
  • Pumping mechanism : Linear Peristaltic
  • Drop Sensors : External ‘Air in line’
  • Detector : Internal
  • Display : LCD and 7 Segment LED Display
  • Safety features : Free flow protection
    Excess / Less Alarm
    Air in Line Protection
    Sensor Malfunction Protection
  • I.V set ml conversion : Adult I.V sets – 12 to 26 drops/ml in steps of 0.5
    Micro I.V sets – 50 to 85 drops/ml in steps of 1
  • I.V set tubing : Accepts all Brands of I.V set
  • Drop rate range : 1 to 150 drop/min for Adult
    1 to 100 drop/min for Micro
  • Volume rate range : 0.5 to 1200 ml/hr for Adult
    0.1 to 300 ml/hr for Micro
  • Drop resolution : 1 drop/min
  • Bolus Function : Auto Bolus, Purge Bolus
  • Bolus Flowrate : 10 to 1200mL/Hr – Adult
    10 to 300mL/Hr – Micro
  • Flow rate resolution : Sequential press
  • Adult : 0.5 to 20ml/hr Step 0.1ml/hr
    20 to 1200ml/hr Step 1ml/hr
  • Micro : 0.1 to 300ml/hr Step 0.1ml/hr
  • Press & hold : Adult – 0.5 to 20ml/hr Step 1 ml/hr
    Adult – 21 to 50ml/hr Step 2 ml/hr
    Adult – 51 to 100ml/hr Step 5 ml/hr
    Adult – 101 to 300ml/hr Step 10 ml/hr
    Adult – 301 to 1200ml/hr Step 25 ml/hr
  • Micro : 0.1 to 20ml/hr Step 1 ml/hr
    21 to 50ml/hr Step 2 ml/hr
    51 to 100ml/hr Step 5 ml/hr
    101 to 300ml/hr Step 10 ml/hr
  • Target Volume : 1 to 9999ml
  • Target Volume steps : 0.5 to 20ml/hr Step 1 ml/hr
    21 to 50ml/hr Step 2 ml/hr
    51 to 100ml/hr Step 5 ml/hr
    101 to 300ml/hr Step 10 ml/hr
    301 to 1200ml/hr Step 25 ml/hr
  • Bolus Volume : 0.1 to 1000mL
  • Elapsed time : 00:00 to 99:59 Hr
  • Keep vein open (KVO) : Off to 9.9ml/hr steps 0.1ml/hr
  • Battery charging period : 16 hrs automatic
  • Battery type : Rechargeable Ni-MH 14.4V 800mAh, Built in & standard
  • Alarm indication for : Target volume, Target time, Excess flow, Less flow, Air in line, Battery low, KVO
  • Purge Flow : Flushing of IV tube possible
  • Menu Driven : Self Guided / Help Assisted Interactive Functions , Self Diagnosis of Alarm Causes
  • Housing : ABS plastic
  • Dimension : 148mm x 110mm x190mm
  • Weight : 2.15 kg
  • Certification : CE, ISO 13485:2003, ISO 9001:2008