Syringe Pumps - 404

AKAS syru pump 404 has been designed to combine high level of safety and performance with very simple & reliable operation. AKAS syru pump 404 offers comprehensive range of features making it ideal for general critical care & neonatal infusion where accuracy is important.

ACCURATE & USER FRIENDLY
  • Syringe-size
    Accepts 10,20,30 & 50/60 mL syringes
  • Automatic syringe size detection
    Detects the size of syringe automatically to avoid manual error in data feeding
  • Custom programmable syringe
    Unspecified syringe brand can be programmed by non technical staffs at hospital itself to get accurate flow rate with unspecified brands.
  • Can be programmed during infusion.
  • Five programmable mode.
  • Bolus facility
    Bolus facility is available in automatic mode as well as manual mode
  • Target volume setting
    The volume to be infused (VTBI) can be preset.
  • Target time setting
    The infusion can be limited by duration its target time setting
  • Elapsed time display
    The duration of infusion is displayed in hours and minutes
  • Infused volume display
    We volume infused in to the patient is displayed in terms of mille litters
  • Built in rechargeable battery
    Rechargeable battery backup infuse safe drug delivery interminant A/C power supplies
  • Upgradable to PCA
    Plug in upgradation possible for Patient Control Analgesia.
  • Variable occlusion pressure
    9 occlusion levels can be programmed.
  • Buzzer volume
    The volume of Buzzer sound / Alarm sound can be varied
  • Flow rates
    Flow rates as low as 0.1 mL/Hr can be set
  • Volume Overtime Setting
    The volume to be infused over a period of time can be set and the machine will automatically calculate the constant flow rate for infusion during the period of time.

Syru Pump 404
SPECIFICATIONS
AKAS Syru Pump 404 Product specification

Description

AKAS syru pump 404

Power Supply

AC Power source 180V to 270V 50Hz
Automatic changeover to internal
Battery at less than 180 V.

Battery NiCd 12V rechargeable battery used.
Operates on battery for 4 hrs.
@ 50mL/Hr flow syringe.

Power Consumption

AC Power Source0.1 Amps (max).
7VA (maximum consumption).

Applicable Syringe

10mL,20mL,30mL & 50mL Syringe from JMS, Braun, Dispovan & Custom programmable Syringe.

Custom Programmable Syringe Programmable to any syringe brand to ensure accurate infusion on all syringe brands programming is simple and may be programmed on field by technician. Syringe size detection is automatic.

Flowrate Range

0.1-120.0 ml/Hr (10ml Syringe)
0.1-200.0 ml/Hr (20ml Syringe)
0.1-300.0 ml/Hr (30ml Syringe)
0.1-420.0 ml/Hr (50ml Syringe)
Adjustable in 0.1 ml increments

Infused Volume Range

0.1- 999.9 ml

Elapsed Time

Visual Display of Elapsed time
from 00.00 to 99.59(hrs.min)

Accuracy

Mechanical Accuracy ±1%
Including Syringe ± 3%

Bolus

Auto Bolus : Programmable by user from 0.1ml to 10ml in 0.1 increment.
Purge Bolus : Activated as long as Bolus Key is Pressed.

Bolus Rate

Programmable by user
100 mL/Hr 10 mL Syringe
160 mL/Hr 10 mL Syringe
240 mL/Hr 10 mL Syringe
420 mL/Hr 10 mL Syringe

Bolus Volume

Programmable by user
0.1mL to 5 mL in 0.1 mL increments (auto bolus)

Five Programmable Mode

Dosage can be stepped up or stepped down by five intervals programmed by user. The intervals can be specified by time or volume.

KVO Programmable by user from 0.0ml/Hr to 9.9ml/Hr in 0.1 ml increment.
Occfusion Pressure 10 step selection from OFF to 9 for occfusion sensitivity.

Alarms

AL1 - syringe holder distributed during infusion
AL2 - Target Volume reached
AL3 - Target time reached
OFF - Battery discharged
AL5 - Motor unable to drive
AL6 - End of Syringe
AL7 - PCA probe disconnected (optional)
AL8 - Occlusion

Parameter Combination Setting

Type I: set Flow Rate only
Type II: Set Flow Rate & Target volume
Type III: Set Flow Rate & Target Time
Type IV: Set target volume and target time thereby the flow rate is automatically calculated & set.
Type V : Can vary the set flow rate, Target volume & Target time while infusion.

Indication

Audible & Visual indication for
1. Near Empty
(3 mins before and of Syringe)
2. Battery low 10 mins before full discharge.
3. Operation on battery

Special Functions Adjustable buzzer volume
(OFF to 9) Last data retrievable

PCA

An optional Feature
10 to 100 mL/Hr (10ml Syringe)
10 to 160 mL/Hr (20ml Syringe)
10 to 240 mL/Hr (30ml Syringe)
10 to 420 mL/Hr (50ml Syringe)
Target volume per dose can be present from 0.1 to 10ml in 0.1 mL increments minmum time interval between two doses cab be preset to avoid over infusion. Time interval from 00.00 to 24.00 (hrs.min) in steps of 1 min patient history of delivered and non delivered does can be displayed.

Safety Testing

IEC 601-01

Fuse

T 50 mA / 250 V

Dimension

275 x 161 x 112

Weight

2.5kg

Accessories

Power Chord
operator's manual

   
Buy Online